Shindaiwa DGW310MC Welder User Manual


 
23
8-2. Polarity
There are 2 welding output terminals + and
-
.
Select the polarity according to the operation, referring to the table below.
Caution
Welding Rods
Application Connection
- to Holder (Rod)
Normal
General Welding such as
construction + to Earth (Material)
Thin Plate, Build-UP Welding
- to Earth (Material)
Reverse
Stainless Steel + to Holder (Rod)
8-3. Connection – Welding Cable
Danger: Electric Shock
Before connecting or disconnecting welding cable to terminal, stop the engine and
Remove the engine key. A person performing should always keep the key.
1. Stop the engine
2. Connect a cable to a crimping terminal, a rod holder and
a material holder.
3. As to DGW310DMC, connect the cable
referring the chart below.
ECO (Single) Single Dual
Rod
Φ2.0 φ4.0
Rod
Φ2.6 φ6.0
Rod
Φ2.0 φ4.0
Welding Output
Terminal A
Welding Output
Terminal A
Welding Output Terminal
A
&
Welding Output Terminal
B
Caution
Be sure to crimp a crimping terminal to a cable and connect the cable to welding cable to welding
output terminal. Otherwise the terminal may burn out by the heat due to insufficient connections.
Use a cable with a crimping terminal. To weld binding bare wires to an output terminal, the terminal
may burn out by the heat caused by insufficient connections and also bare wires may touch the
bonnet to bring short-circuit.
Rod Holder Cable
Crimping terminal
Holder