Shindaiwa DGW310MC Welder User Manual


 
36
(6) Change Coolant/Water
Change At 2000 hrs or 2 yrs
Total capacity: 3L (including Sub Tank: 0.6L
1 Open the top door.
2 Remove the radiator cap.
3 Remove the water drain plug.
4 After draining all the water, reinstall
the water drain plug.
Caution
Change the packing whenever changing
coolant/water.
Packing Part No.: 6C09058961 (Kubota)
5 Replace all the water in the sub tank.
6 Fill water to Max Level (to the water inlet)
7 Reinstall the radiator cap.
8 Close the top door.
Caution
After supplying water, keep the engine drive for
a while to check no water leakage and then stop the engine
Danger: Electric Shock
.
When performing check and maintenance, always stop the engine
Caution: Injuries
When performing check and maintenance always stop the engine
Caution: Fire/Burns
Keep the equipment far away from fire.
Do not touch the engine and muffler during operation or immediately after stopping the equipment for the
temperature reaches extremely high.
12. Long-Term Storage
Top Door
Radiator
Cap
Water Inlet
Sub Tank
Coolant Drain Plug