Woodstock W1770 Saw User Manual


 
-56-
W1770 21" Bandsaw w/Foot Brake
SERVICE
Wiring Diagram
PWR
ON
OFF
CONTROL PANEL
(viewed from behind)
A
AMP
RESET
96
1/2
T1/2 T3/6
NO14
3/4
T2/4
L1/1
L3/5
NO13
L2/3
5/6
95
18
22
26
NC15
SDE
NC16
MAG
SWITCH
ASSEMBLY
SDE MPE-18
L1
L1
L2
L2
Ground
Ground
Ground
Ground
220V
MOTOR
Ground
Hot
Hot
L6-30 PLUG
(as recommended)
220 VAC
LIMIT SWITCH (NC)
FOOT BRAKE
NC
SDE RA-30
18-26
SDE
MA-18
220V
POWER
SUPPLY
JUNCTION
BLOCK
SHOCK HAZARD!
Disconnect power before servicing electrical
parts. Touching electrified parts will result in
severe burns, electrocution, or death.
21
1211
23 24
13
22
14
21
13
22
14
21
13
22
14
98
G
X
Y
CONTACTOR
THERMAL RELAY
Start
Capacitor
400MFD
250VAC
Run
Capacitor
45MFD
350VAC
Figure 83. Capacitors.
See Figure 80,
Page 55
See Figure 80, Page 55
See Figure 79, Page 55
(Figure 82,
Page 55)
(Figure 81,
Page 55)
(Figure 78,