Stanley Black & Decker RW30 Welding System User Manual


 
RW30 USER MANUAL - 23
J.SAURON
TRANSLAMATIC RW30
08 JS 063* du 17/12/2008 02/04/2009
PAGE : 9/68
Coder’s pulses defect Check the coder connexion on the right side and
on the bottom of the interface card (J3 connector
side).
Replace the interface card.
Axis engine’s cards Check if the card’s lights are alight during a
moving command.
Switch the connexions between the 2 engines and
the recheck the moving of the torch (the
movements are reversed)
Call our After Sales Dpt
Interface card Check all the connexions
Check if the card’s lights are alight during a
moving command.
Replace the interface card
Call our After Sales Dpt
Couple Engine + Coder. Replace the couple Engine + Coder.
No wire feeding
PROBABLE CAUSE CHECKS AND REMEDYS
The PGA Close or set up the wire’s pressure with the PGA’s
rollers.
The Roll n’ Roll Check the wire’s drum and/or set the Roll n’ Roll
brake
Cables Check the connexions and the PGA‘s alimentation
cable
Charlie box Try with another Charlie box
Check if the welding command light is alight on
the interface card
Link cable between the TRANSLAMATIC and
the Charlie box
Check the connexions or/and change the cable
Welding trigger opened (Welding control
connector)
Check the closing of the welding trigger with an
ohmeter (value < to 20 ohms) between the pins 3
and 4 of the 7 points connector or C an D of the
Amphenol connector 19 points.
Stabilized alimentation out of service Check the alimentation’s tension, normally 27V in
CC.
Call our After Sales Dpt
Wire feeding OK but no welding
PROBABLE CAUSE CHECKS AND REMEDYS
Ground cable Make sure that the ground cable is well connected
Interface card Check if the card’s lights are alight during a
moving command.
Call our After Sales Dpt
Arc welder generator Check the parameters and the good operating of
the arc welder
Call our After Sales Dpt
FOR ANY INTERNAL INTERVENTION OUT OF THESE POINTS ABOVE,
THANKS TO CALL OUR AFTER SALES DEPARTMENT
TROUBLESHOOTING