Installing the Inverter/Charger
This guide for use by qualified personnel only.
Step 5: Connecting the Battery Temperature Sensor (BTS)
Installing a battery temperature sensor (BTS) extends the life of a
battery by preventing overcharging in warm temperatures and
undercharging in cold temperatures. With a BTS monitoring the
battery temperature, the voltage delivered to the battery is adjusted
according to the battery’s actual temperature.
The BTS has a self-adhesive backing and attaches to the side of the
battery. A 7.6 m cable is supplied with the BTS.
Mounting Options
You can mount the BTS in one of two ways:
Mounting the sensor to the negative battery post allows the
internal battery temperature to be sensed and provides the most
accurate results.
Attaching the sensor to the side of the battery using the self-
adhesive backing also provides good results in most situations.
Figure 10 BTS with Cable
EQUIPMENT DAMAGE
Use only the Freedom SW 230V-compatible Battery Temperature Sensor
(BTS). To order a spare BTS, call customer service and order part number
809-0946.
Failure to follow these instructions can damage the unit and/or
damage other equipment.
Connector
Sensor cable
Sensor