STAAD Commands and Input Instructions
Section 5
5-410
5.51.2 Concrete Design-Parameter Specification
Purpose
This set of commands may be used to specify parameters to control
concrete design for beams, columns and individual plate elements.
General format:
ACI
AUSTRALIA
BRITISH
CANADIAN
CHINA
EUROPE
COD
E FRENCH
GERMAN
INDIA
JAPAN
MEXICO
NORWAY
MEMBER memb/elem list
parameter-name f
1
( ALL )
Description
Parameter-name refers to the concrete parameters described in
Table 3.1.
f
1
= is the value of the parameter. Wherever applicable, this value
is input in the current units. The UNIT command is also
accepted during any phase of concrete design.