Carrier 09RH Air Compressor User Manual


 
38
Table 29 Condenser Physical Data
LEGEND NOTES:
1. Based on R-22 at 105 F condensing, 85 F entering water temperature,
10 F rise. The 09RH097 is rated at 10.6 F rise in order to stay within the
recommended water velocity range.
2. 90 F liquid, 80% filled.
3. Purge and liquid test cocks furnished on all condensers.
4. 5F40 and larger condensers have cleanable and renewable tubes.
Table 30 Max Condenser Tube Water Velocity
Table 31 Condenser Gpm at Various Water Velocities*
LEGEND
*Within ARI Standard recommendations.
Double circuit for 5F20 and 30.
**Single circuit for 5F20 and 30.
Water velocity formulas: (Use for velocities above 12 fps.)
CONDENSER SIZE 5F20 5F30 5F40 5F60
09RH
027
09RH
043
09RH
054
09RH
070
09RH
084
09RH
097
09RH
127
NOMINAL CAPACITY (Tons) 9.8 14.3 22.1 27.3 47.0 71.0 87 103 120 135 198
CONDENSER TYPE Shell and Coil Shell and Tube
Net Weight (lb) 77 114 246 340 493 686 807 863 1028 1360 1635
SHELL
Outside Diameter (in.) 8
3
/
8
8
3
/
8
8
5
/
8
8
5
/
8
10
3
/
4
12
3
/
4
12
3
/
4
12
3
/
4
14 14 18
Length (in.) 28
5
/
8
39
5
/
8
63 74 77
1
/
8
79
1
/
4
95
1
/
4
95
1
/
4
99
3
/
8
123
1
/
8
100
1
/
2
TUBES OR COIL Coil Tubes; Integral Fin; 40 Fins per Inch
Number (Total) 2 2 26 30 44 66 66 80 94 94 156
Length (in.) 295
1
/
4
387
5
/
8
56
5
/
8
67
5
/
8
70
5
/
32
70
5
/
32
86
5
/
32
86
5
/
32
86
5
/
32
109
7
/
8
86
5
/
32
No. of Water Circuits 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1 2 or 1
No. of Water Passes ——4 or 8 4 or 8 3 or 6 3 or 6 3 or 6 3 or 6 3 or 6 3 or 6 3 or 6
CIRCUIT LENGTH (ft)
Single Circuit 49.2 64.6 ————
Double Circuit (each) 24.6 32.3 ————
Minimum (4 or 3 Pass) ——18.0 21.6 17.0 16.9 20.9 20.9 20.8 26.7 20.8
Maximum (8 or 6 Pass) ——36.0 43.3 34.0 33.8 41.8 41.8 41.6 53.4 41.6
SURFACE
AREA (sq ft)
Water Side 8.6 13.4 20.5 30.7 48.8 70.8 87.7 108.4 130.3 165.2 207.7
Refrig Side 43.6 65.8 66.4 99.5 158.0 229.0 284.0 352.0 422.5 536.3 672.4
MAX WORK.
PRESS. (psig)
Water Side 150 250
Refrig Side 385
MAX REFRIG
STORAGE
CAP. (lb)
R-12 30 41 80 94 163 217 268 239 309 397 527
R-22 27 37 74 86 148 197 243 226 280 360 478
R-502 28 38 75 87 150 200 247 229 284 366 485
MIN REFRIG
OPERATING
CHARGE (lb)
R-12 2.0 3.0 14.0 16.0 37.0 41.0 51.0 51.0 78.0 100 126
R-22 1.8 2.7 12.7 14.5 33.0 37.0 46.0 46.0 71.0 91 114
R-502 1.9 2.9 13.1 15.0 34.4 38.2 47.3 47.3 73.0 94 118
WATER
CONN (in.)
Single
Ckt or
Min Pass
Inlet
1
/
2
FPT
3
/
4
FPT (2) 1
1
/
4
FPT (2) 1
1
/
4
FPT (2) FPT (2) 2 FPT (2) 2 FPT (2) 2 FPT (2) 2
1
/
2
IPS (2) 2
1
/
2
IPS (2) 3 IPS
Outlet
1
/
2
FPT
3
/
4
FPT 1
1
/
2
FPT 1
1
/
2
FPT 2
1
/
2
FPT 3 FPT 3 FPT 3 FPT 4 IPS 4 IPS 5 IPS
Double
Ckt or
Max Pass
Inlet (2)
1
/
2
FPT (2)
3
/
4
FPT 1
1
/
4
FPT 1
1
/
4
FPT 2 FPT 2 FPT 2 FPT 2 FPT 2
1
/
2
IPS 2
1
/
2
IPS 3 IPS
Outlet (2) 1 MPT (2) 1 MPT 1
1
/
4
FPT 1
1
/
4
MPT 2 FPT 2 FPT 2 FPT 2 FPT 2
1
/
2
IPS 2
1
/
2
IPS 3 IPS
REFRIG
CONN
Gas
Inlet
Type Female-Solder
ODF (in.) 1
1
/
8
1
3
/
8
1
3
/
8
1
5
/
8
2
1
/
8
2
5
/
8
3
1
/
8
3
1
/
8
3
1
/
8
3
5
/
8
3
5
/
8
Liquid
Outlet
Type Female-Solder 2-Bolt Valve 4-Bolt Valve
ODF (in.)
1
/
2
1
/
2
7
/
8
1
1
/
8
1
3
/
8
1
3
/
8
1
5
/
8
1
5
/
8
2
1
/
8
2
1
/
8
2
1
/
8
RELIEF VALVE (in.)
3
/
8
MPT
3
/
8
MPT
1
/
2
FPT
1
/
2
FPT
5
/
8
FL
5
/
8
FL
5
/
8
FL
5
/
8
FL
3
/
4
FL
3
/
4
FPT (2)
3
/
4
FPT
WATER DRAIN & VENT PLUG (in.) ——
1
/
4
1
/
4
3
/
8
3
/
8
3
/
8
3
/
8
3
/
8
3
/
8
3
/
8
WATER REG CONN (in.)
1
/
4
FL Flare
FPT Female Pipe Thread (in.)
IPS Iron Pipe Size (Butt-welded connection)
MPT Male Pipe Thread (in.)
ODF Outside Diameter Female (in.)
Psig Pounds Per Square Inch Gage
OPERATING HOURS
PER HOUR
MAXIMUM TUBE
WATER VELOCITY
(fps)
Up to 1500 15.0
2000 14.0
3000 13.0
4000 12.0
6000 10.0
8000 8.0
CONDENSER
MINIMUM PASS MAXIMUM PASS**
Water Velocity (fps)
3579101235791012
5F20 61115202224 3 5 8101112
5F30 81522293232 4 7 11141616
5F40 16 27 39 50 56 64 8 14 19 25 28 32
5F60 20 35 50 65 72 80 10 17 25 32 36 40
09RH027 42 70 98 126 140 168 21 35 49 63 70 84
09RH043 63 105 147 189 210 252 31.5 52.5 73.5 94.5 105 126
09RH054 63 105 147 189 210 252 31.5 52.5 73.5 94.5 105 126
09RH070 79 131 183 236 262 316 39.5 65.5 91.5 118 131 158
09RH084 93 155 216 279 310 372 46.5 77.5 108 139.5 155 186
09RH097 93 155 216 279 310 372 46.5 77.5 108 139.5 155 186
09RH127 148 247 346 445 494 592 74.0 123.5 173 222.5 247 296
ARI Air Conditioning and Refrigeration Institute
5F20 Condenser: V =
gpm x 0.92
no. of circuits
5F40 through 09RH127: V =
gpm x passes x 1.06
total tubes
5F30 Condenser: V =
gpm x 0.65
no. of circuits