Fluke PM-3380B Sander User Manual


 
COMMAND REFERENCE 4 - 113
TRACe:POINts
Syntax:
TRACe:POINts <source_trace> [,<acquisition_length>]
Alias:
DATA:POINts <source_trace> [,<acquisition_length>]
<source_trace> CHn | Mi_n
n = 1 .. 4
i = 1 .. 8 (standard memory)
i = 1 .. 50 (extended memory)
<acquisition_length> <NRf> | MINimum | MAXimum
<NRf> 512 | 2048 | 4096 | 8192
(standard memory)
512 | 8192 | 16384 | 32768
(extended memory)
Notes: - 512 is the default value.
MINimum Length becomes 512 points.
MAXimum Length becomes 8192, if no extended
memory is available.
Length becomes 32768, if extended
memory is available.
Query form:
TRACe:POINts? <source_trace> [,MINimum | MAXimum]
<source_trace> CHn | Mi_n
n = 1 .. 4
i = 1 .. 8 (standard memory)
i = 1 .. 50 (extended memory)
If MINimum was specified, the minimum possible trace length is
returned.
If MAXimum was specified, the maximum possible trace length is
returned.
Response:
<acquisition_length>