Code Name Type Causes Fixes
Trigger
Condition
E3 Improper
Machine Cali-
bration
Alarm Machine has not been
calibrated or has been
calibrated incorrectly.
Perform pump position
entries in Position Calibra-
tion Screen. Retract posi-
tion must be less than
metering tube position, which
should be less than the fully
extend position.
When
requesting a
dispense
operation.
E4 Bad Linear
Position Sen-
sor
Alarm 1. Connection to position
sensor disconnected.
2. Power to position sen-
sor interrupted.
3. Bad position sensor.
1. Verify connections to the
sensor.
2. Verify proper readings from
sensor on setup screen 1.
3. Replace sensor
Invalid read-
ings from the
sensor.
E5 Stuck key Alarm 1. Key is in an active
state.
2. Tactile switch on LCM
is shorted or broke.
Replace LCM Module. If key is
detected to
be active for
more than 30
seconds.