Graco 334135B Saw User Manual


 
Appendix C - LCM Setup Screen Overview
64 334135B
Appendix C - LCM Setup Screen Overview
Password Entry Screen
If a password is programmed into the LCM, the user will
be prompted to enter a password. If no password has
been entered (all 0's on the password set/ clear setup
screen), this screen will be bypassed.
Position Calibration Screen
This screens is used to set or observe the proper posi-
tions on the linear position sensor for full extend, retract
and entrance into the metering tube. All valid entries
must be present for the machine to operate. The extend
position must be greater than the metering tube posi-
tion, which must be greater than the retract position.
When the position is accepted, the real time position
sensor reading in the middle of the screen will be trans-
ferred to above the graphic for the corresponding posi-
tion. The process needs repeated for all three
positions.
Phasing Shot Calibration Screen
This screen is to instigate a phasing shot, and to define
the percentage of stroke for a phasing shot.
Open Dispense Valve Position Calibration
Screen
This screen is to set or view the position with reference
to the metering tube entrance where the dispense valve
is opened during the forward stoke of the pump.
Dispense Amount Prohibit and View Cycle
Counter Screen
This screen will enable the user to lock out or enable the
operator to change stroke percentage for the shot mode
run screen. The user will also be able to view the
machine cycle counter.
Setup Screen Password Set/Clear Screen
This screen will allow the user to view, set or clear (by
entering four 0's) the password. Setting a new password
or clearing the password feature is identical to the
method used to enter the setup screen, if a non-zero
password is present.