Graco Inc. 300E Paint Sprayer User Manual


 
Repair / Réparation / Reparación
36 313314B
Sprayer does not run at all Control is commanding motor to run
but motor shaft does not rotate.
Possibly locked rotor condition, an
open connection exists between
motor and control, there is a
problem with motor or control board,
or motor amp draw is excessive.
With prime valve open and pressure
relieved, start and stop motor 15
times using set point potentiometer
(pressure switch). If motor restarts
each time at no load, motor may be
bad and must be tested (see Step
1). If motor will not restart every
time, board is at fault. Replace
circuit board.
1. Remove pump and try to run sprayer. If motor runs,
check for locked or frozen pump or drive train.
If sprayer does not run, continue to step 2.
2. Set sprayer to OFF and disconnect power to sprayer.
3. Disconnect motor connector(s) from control board
socket(s). Check that motor connector and control
board contacts are clean and secure. If contacts
are clean and secure, continue to step 4.
4. Set sprayer to OFF and spin motor fan 1/2 turn.
Restart sprayer. If sprayer runs, replace control
board. If sprayer does not run, continue to step 5.
5. Perform Spin Test: Test at large 4-pin motor field
connector. Disconnect fluid pump from sprayer. Test
motor by placing a jumper across pins 1 & 2. Rotate
motor fan at about 2 revolutions per second. A cogging
resistance to motion should be felt at the fan.
The motor should be replaced if no resistance is felt.
Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4
(the green wire) is not used in this test. If all spin test
is positive, continue to step 6.
Digital display shows E=05
Control board status light blinks
5 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
If check is OK, go to next check
WHAT TO DO
When check is not OK, refer to this column