Graco Inc. 300E Paint Sprayer User Manual


 
Repair / Réparation / Reparación
38 313314B
Sprayer does not run at all Allow sprayer to cool. If sprayer runs
when cool, correct cause of
overheating. Keep sprayer in cooler
location with good ventilation. Make
sure motor air intake is not blocked.
If sprayer still does not run, follow
Step 1.
NOTE: Motor must be cooled down for the test.
1. Check thermal device connector (yellow wires)
at control board.
2. Disconnect thermal device connector from control
board socket. Make sure contacts are clean and
secure.
3. Measure resistance of the thermal device. If reading
is not correct, replace motor.
Check Motor Thermal Switch: Unplug thermal
wires. Set meter to ohms. Meter should read the
proper resistance for each model (see table below).
4. Quick test for Ultras
5. Reconnect thermal device connector to control
board socket. Connect power, turn sprayer ON and
control knob 1/2 turn clockwise. If sprayer does not
run, replace control board.
Digital display shows E=06
Control board status light blinks
6 times repeatedly
Sprayer does not run at all Check the connections. Control
is not receiving a motor position
sensor signal
1. Turn power OFF.
2. Disconnect m-p sensor and inspect for damage.
3. Reconnect sensor.
4. Turn power ON. If error continues, replace board.
Digital display shows E=09
Control board status light blinks
9 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
If check is OK, go to next check
WHAT TO DO
When check is not OK, refer to this column
Resistance Table:
Ironman 300E 8.2k ohms
695 0 ohms
795 2k ohms
1095 3.9k ohms
1595 6.2k ohms
-
ti13140a