Graco Inc. PRO Auto Xs AA Paint Sprayer User Manual


 
Installation
309298J 17
Check Fluid Resistivity
Graco Part No. 722886 Resistance Meter and 722860
Probe are available as accessories to check that the
resistivity of the fluid being sprayed meets the require-
ments of an electrostatic air spray system.
Follow the instructions included with the meter and
probe. Readings of 25 megohms-cm and above provide
the best electrostatic results.
Check Fluid Viscosity
To check fluid viscosity you will need:
a viscosity cup
a stopwatch.
1. Completely submerge the viscosity cup in the fluid.
Lift the cup out quickly, starting the stopwatch as
soon as the cup is completely removed.
2. Watch the stream of fluid coming from the bottom of
the cup. As soon as there is a break in the stream,
shut off the stopwatch.
3. Record the fluid type, elapsed time, and size of the
viscosity cup.
4. If the viscosity is too high or too low, contact the
material supplier. Adjust as necessary.
Install the Fabric Cover
1. Install a fabric cover (XX) over the front of the gun
and slide it back to cover the exposed tubing and
hoses at the back of the manifold. See F
IG. 9..
2. Route the exhaust tube (YY) outside the cover. This
enables you to monitor the exhaust tube for the
presence of any paint or solvent. See Check for
Fluid Leakage on page 28. Strap down the exhaust
tube to prevent it from moving around.
Fig. 9. Fabric Cover
WARNING
Fire, Explosion, and Electric Shock Hazard
Check the fluid resistivity in a non-hazard-
ous area only. Resistance Meter 722886
and Probe 722860 are not approved for use
in a hazardous area.
Failure to follow this warning could cause
fire, explosion, or electric shock and result
in serious injury and property damage.
TI1736A
TI1716A
YY
YY
XX