Grizzly T10687 Cordless Saw User Manual


 
Model T10687 (Mfg. Since 10/12)
-27-
4. Lift cover off motor to access brush wires.
Brush Wires Brush Wires
6. Using a flat-end screwdriver, carefully posi-
tion screwdriver shaft under brush spring and
evenly against both screw posts. Lift brush
spring straight up, and gently pull brush wire
to slide brush out of holder.
Brush
Slide Brush Out
Screw Posts
Brush
Spring
5. Disconnect brush wires from motor wires by
carefully pulling apart terminal connectors.
DO NOT pull on wires! (Use needle-nose pli-
ers if needed to grip terminal connectors.)
Only grasp terminal connectors (not wires)
when disconnecting brush wire. Pulling on
wires may cause them to break or separate
from terminal connectors.
Brush
Wire
Motor
Wire
Only Grasp Here When
Disconnecting Terminals
7. Install replacement brushes in holders with
wire-side in down position. Move brush
springs back to their original position against
brushes.
8.
Connect replacement brush wires to motor
wires.
9.
Route motor wires around both positions
shown below. This helps ensure motor wires
do not touch spinning motor components dur-
ing operation.
Position 2
Position 1
10. Re-install motor cover and secure the four
screws.
Congratulations! The brush replacement proce-
dure is complete. Test run the saw to ensure that
it is working properly.
If the saw does not start or run properly after
installing the new brushes, disconnect it from
power and immediately contact Grizzly Tech
Support for assistance.