HP (Hewlett-Packard) 4.5 Welding System User Manual


 
System Event Analyzer
2.3 SEA Known Issues
Rev. 9/8/06
Web-Based Enterprise Services Release Notes 2–7
Running DECevent and WEBES on the same machine results in duplicate callouts to the CSC
when event notification occurs. To resolve this problem, you can choose to only start one of
the applications at boot time.
OpenVMS
To prevent DECevent from starting on an OpenVMS platform, use the following procedure:
1. Edit the startup script,
sys$startup:decevent$startup.com.
2. Insert the following code at the beginning of the file:
Note
Verify the existence and format of the SYS$NODE logical before performing this
operation.
$ node = F$TRNLNM(“SYS$NODE”,,,,,)
$ IF (node .EQS. “nodename1::”) THEN EXIT 1
Replace nodename1 with the name of the node that should not run DECevent. If there are
multiple cluster nodes that need to be modified, add a similar IF line for each affected
cluster node.
To prevent WEBES from starting on an OpenVMS platform, use the following procedure:
1. Edit the startup script,
sys$startup:desta$startup.com.
2. Insert the following code at the beginning of the file:
$ node = F$TRNLNM(“SYS$NODE”,,,,,)
$ IF (node .EQS. “nodename1::”) THEN EXIT 1
Replace nodename1 with the name of the node that should not run WEBES. If there are
multiple cluster nodes that need to be modified, add a similar
IF line for each affected
cluster node.
2.3.1.8 Upgrading to an Operating System that Supports
Drape or Indictment
Some versions of OpenVMS do not support the Drape or Indictment services. If you upgrade
from a version that does not support the services to a version that does, you must modify your
WEBES installation. See the System Event Analyzer User Guide for information on modifying
the installation.