Husqvarna DXR-310 Power Hammer User Manual


 
TECHNICAL DATA
Guide values for mains connection
The power cable must be dimensioned by a quali ed person in accordance with national and local regulations. The
mains socket to which the machine is connected must be dimensioned for the same amperage as the machine’s
electrical socket and extension cable, e.g. a 63 A electrical socket must be preceded by a 63 A fuse.
Nominal
voltage from
power source
Min.
voltage
at machine
Cable area Starting
current
Motor output Setting
thermal over-
load relay
Max. cable
length during
operation
V V mm
2
A kW A m
400 380 6 90*
50 Hz
22,0 44 163
400 380 10 90* 22,0 44 272
400 380 16 90* 22,0 44 435
460 440 6 90*
60 Hz
25,3 44 163
460 440 10 90* 25,3 44 272
460 440 16 90* 25,3 44 435
* Two phases soft start. The directly related phase can be loaded up to 30% more.
The hydraulic system’s pressure
Type of pressure Pressure, Bar
Pump pressure
The pressure in the pipes between pump and main stop
valve. The pressure varies between pressure at rest and
max. pressure depending on which hydraulic functions
are being used.
Tool, max* 250
Rotating function 170
Outrigger down/up 250/200
Arm functions 200
Pressure cut-off
Functions equipped with pressure cut-off can never be
run at a higher pressure than that indicated. The follow-
ing functions are equipped with pressure cut-off for the
respective pressure level.
Telescopic arm 180
(External hand tool - option) (140)
Pressure at rest
The pressure that the pump delivers when no function is
activated and the pump around valves is shut.
20 ±1
50
- English