CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
The welding arc is variable or
hunting.
Poor arc striking with sticking or
blast-offs. The weld bead may be
ropy and narrow.
1. Check the welding cables for
loose or faulty connections.
2. Make sure the wire feed speed,
voltage, polarity and shielding
gas are correct for the process
being used.
3. Check for mechanical restric-
tions in the wire feed path.
4. Make sure the welding power
source is functioning properly.
1. Make sure the wire feed speed,
voltage, polarity and shielding
gas are correct for the process
being used.
2. Make sure the welding power
source is functioning properly.
3. Make certain the gas solenoid is
operating properly and the gas
flow rate is correct for the pro-
cedure.
4. The welding gun may be faulty.
Check for gas leaks or replace
gun.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.