Lincoln Electric IM544-B Welding System User Manual


 
E-2
TROUBLESHOOTING
E-2
COMMANDER 400
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
ENGINE PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Major Physical or Electrical Damage
is Evident.
Engine will not “crank”.
Engine will “crank” but not start.
Engine shuts down shortly after
starting.
Battery does not stay charged.
1. Contact your Local Lincoln
Authorized Field Service Facility.
1. Battery is low. Charge Battery.
2. Loose battery cable connections.
Inspect, clean and tighten.
1. Out of fuel. Fill prime tank.
2. Fuel shut off valve is in off
position.
3. High oil temperature (Indicator
light lit. Check engine cooling
system. (Consult engine service
dealer.
4. Low battery voltage.
1. Low fuel. (Indicator light lit) Add
fuel.
2. Low output of battery charging
alternator. (Indicator light lit)
Check
cooling blower belt. Replace
if neccessary.
3. High oil temperature (Indicator
light lit). Check engine cooling
system. (Consult engine service
dealer.
1. Faulty battery. Replace
Contact your Local Lincoln Authorized
Field Service Facility for technical
troubleshooting assistance.