Lincoln Electric IM544-B Welding System User Manual


 
F-5
DIAGRAMS
F-5
COMMANDER 400
CONNECTION DIAGRAM:
ELECTRODE
TO WORK
N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY.
ELECTRODE CABLE
6 PIN
TO WORK
AMPHENOL
AMPHENOL
14 PIN
LN-25
WIRE FEEDER
TO WORK
WORK CLIP LEAD
OPTIONAL K857
REMOTE CONTROL
N.D. ON COMMANDER 400 STICK & WIRE, THE OUTPUT CONTROL SWITCH MUST BE IN THE "WELDING
TERMINALS ALWAYS ON" POSITION .
N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL/REMOTE SWITCH IN "REMOTE" POSITION.
COMMANDER 400 STICK & WIRE / LN-25 ACROSS THE ARC CONNECTION DIAGRAM WITH OPTIONAL K857 REMOTE CONTROL
S22912
12-13-96
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
Keep guards in place.
or service this equipment.
Keep away from moving parts.
Only qualified personnel should install,use
Do not touch electrically live parts.
before servicing.
Disconnect NEGATIVE (-) BATTERY LEAD
Do not operate with panels open.
WARNING