OM-129 647 Page 18
ether1 7/96 − ST-153 382-A / ST-180 933-B
Y Stop engine.
Y Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
er’s safety instructions on
cylinder.
Y Do not use Ether Starting
Aid while engine is running.
Open side door(s).
1 Ether Cylinder
2 Nozzle
Remove cover and clean cylinder
nozzle.
3 Clamp
4 Fitting
5 Cap
6 Valve
Remove cap and clean fitting.
Install cylinder on fitting. Tighten
clamp.
. After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.
Put cap on fitting when cylinder is
removed.
1
2
3
4
6
5
4-8. Installing Ether Cylinder (Optional Ether Starting Aid)
4-9. Remote A/V Control Receptacle RC3
Ref. ST-154 862-A / ST-048 720-K
1 Remote A/V Receptacle RC3
Connect optional remote control to
RC3 (see Section 5-2).
OR
1