Miller Electric 500DX R Welding System User Manual


 
OM-129 647 Page 31
7-5. Adjusting Engine Speed
ST-045 768-B
Engine speed is factory set and
should not require adjustment. Af-
ter tuning engine, check engine
speed with tachometer. See table
for proper no load speed. If neces-
sary, adjust speed as follows:
1 Plastic Cap
2 High Speed Stop Screw
3 Lock Nut
Remove plastic cap from screw.
Loosen nut. Turn screw out (to-
ward front of engine) several turns.
4 Linkage
5 Lock Nuts
Loosen nuts. Start engine and
move linkage until engine runs at
weld/power speed. Tighten nuts.
Y Stop engine.
6 Speed Control Lever
Turn screw in until screw touches
lever. Tighten lock nut on screw
and reinstall plastic cap.
Close side door.
1
3/8 in
243
5
Right Side
6
RPM
1850
Tools Needed:
Engine Speed
(No Load)
Weld/Power
7-6. Servicing Optional Ether Starting Aid
ether2 7/96 ST-153 382-A / Ref. ST-180 933-B / S-0692
Y Stop engine.
Y Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
er’s safety instructions on
cylinder.
If engine does not start in cold
weather, check ether cylinder as
follows:
Remove cylinder from valve.
1 Ether Cylinder
2 Valve
3 Scale
Weigh cylinder to see if it is empty.
Be sure atomizer is not plugged
and valve fitting is clean.
Replace cylinder according to
Section 4-8.
1
2
15 oz33 oz
(935 g) (425 g)
3
Full Empty