6-2. Optional Auxiliary Power Receptacles
Ref. ST-180 933-B / Ref. ST-182 266
. Auxiliary power is not affected
by weld output.
If a circuit breaker continues to
open, contact Factory Autho-
rized Service Agent.
GFCI Receptacle Option
1 120 V 15 A AC GFCI
Receptacle GFCI1
Auxiliary power output and circuit
breaker protection is the same as
standard receptacles (see Section
6-1).
If a ground fault is detected, GFCI
Reset button pops out and
receptacle does not work. Check
for faulty tools plugged in
receptacle. Press button to reset.
. At least once a month, run en-
gine at weld/power speed and
press test button to verify
GFCI is working properly.
Australian And South African
Receptacle Options
2 240 V 10 A AC Australian
Receptacle RC1
3 240 Volt 13 A AC South
African Receptacle RC1
RC1 supplies 60 Hz single-phase
power at weld/power speed. Maxi-
mum output from receptacle is 3
kVA/kW.
4 Circuit Breaker CB1
CB1 protects RC1 from overload. If
CB1 opens, RC1 does not work.
Press button to reset breaker.
British Receptacle Option
5 240 Volt 13 A AC British
Receptacles RC1 And RC2
RC1 and RC2 supply 60 Hz single-
phase power at weld/power speed.
Maximum combined output from
both receptacles is 3 kVA/kW.
6 Circuit Breaker CB1
CB1 protects RC1 and RC2 from
overload. If CB1 opens, the recep-
tacles do not work. Press button to
reset breaker.