Outback Power Systems VFX3024E Battery Charger User Manual


 
36
PRESS <INC> UNTIL 141,
THEN PRESS ENTER.
STACKING SYSTEM EXAMPLES
OutBack Parallel Stacking
Four FXs in a single system are referred to as a Quad Stack.
The FX installed at the bottom of the stack is plugged into Port 1 of the HUB.
The second, third, and fourth FXs are plugged into Ports 2, 3, and 4 respectively.
ADV/PASSWORD-------------
enter the password
132
ENTER INC DEC EXIT
ADV/SETTINGS/WARNING
changes made could adversely
a ect system performance
MAIN----------------------
8:25:04A
SUM STATUS SETUP ADV
ADV/FX/PG2-----------------
choose category:
PG1 GRID GEN PG3
ADV/FX/PAGE 1--------------
choose category:
ADV INV CHGR PG2
ADV----------------------------
choose a device:
FX CC DC MATE
ADV/FX/STACK-----------P02
stack 1-2ph Master
phase
DOWN INC DEC PORT
ADV/FX/STACK---------P01
stack 1-2ph Master
phase
DOWN INC DEC PORT
ADV/FX/PAGE3---------------
choose category:
PG2 AUX STACK PG4
ADV/FX/STACK---------P04
stack OB Slave L1
phase
DOWN INC DEC PORT
ADV/FX/STACK----------P03
stack OB Slave L1
phase
DOWN INC DEC PORT
Push the <PORT> soft key until
Port 01 appears.
Press the <PORT> soft key until
Port 02 appears. Press the <INC>
soft key twice until the stack
phase ob slave L1 screen appears.
Press the <PORT> soft key until
Port 03 appears. Press the <INC>
soft key twice until the stack phase
ob slave L1 screen appears.
Press the <PORT> soft key until
Port 04 appears. Press the <INC>
soft key twice until the stack phase
ob slave L1 screen appears.
At completion, each Slave FX in Ports 2, 3, and 4 will be in parallel with the Master in Port 01. Addi-
tional Slaves can also be programmed as OB Slave L1 following the instructions above. All the Slave FXs
connected to Ports 2, 3, and 4 are now in parallel with the Master in Port 01. Remain in this screen. The
next step is to rank the Slaves in relation to the Master.