5.3 PEAK CHARGE.
5.3.1. Transfer from Main to Topping on Peak voltage.
5.3.1.1. The battery is charged at the main rate for a preset time.
5.3.1.2. When the battery voltage reaches the programmed peak voltage, the
charging current transfers from main to topping.
5.3.1.3. Charging is automatically terminated at the end of the total time
selected (cycle end), or as a fault if:
Battery overtemperature is detected (Overtemp fault).
Battery voltage is in excess of 85V (voltage fault).
Actual charging current differs from the programmed value by
more than 1 AMP (current fault).
NOTE: Charge operation may be terminated at any time by
depressing the (green) reset button.
5.3.2. Stop on Peak Voltage.
5.3.2.1. The battery is charged at the main rate for a preset time.
5.3.2.2. When the battery voltage reaches the programmed peak voltage, the
charging current stops.
5.3.2.3. Charging is automatically terminated at the end of the total time
selected (cycle end), or as a fault if:
Battery overtemperature is detected (Overtemp fault).
Battery voltage is in excess of 85V (voltage fault).
Actual charging current differs from the programmed value by
more than 1 AMP (current fault).
NOTE: Charge operation may be terminated at any time by
depressing the (green) reset button.