Precision Trading 60 R3.0 Battery Charger User Manual


 
Operator Manual, Supercharger 60 R3.0
Page 51 of 62
Adjust R11 as required to reduce the charging
current to zero at a simulated battery voltage of
28.0V
Note: This test can also be performed directly on a
battery (no calibrator required), preferably one that
is “soft” (rapid voltage change). Adjust R11 as
necessary to maintain the battery at the required
voltage (see Verification of Performance, section 7,
page 27).
9.2.5.2.2. R14, PEAK VOLTAGE:.
Connect a CAL-100 Calibrator or a power supply
(capable of producing at least 35V with very little
current) in place of the battery.
Set the calibrator/power supply to 28.5V
Set the Voltage Control Mode to Peak (Transfer).
Set both current selectors to zero
Enter 24 in the cell selector (nominal battery
voltage).
Start the Charger-Analyzer in Dual rate. The current
will rise to the programmed value.
Increase the power supply/calibrator towards 29.4V.
The Charger-Analyzer will switch from Main to
Topping at a battery voltage of 29.4V
Adjust R14 as required to switch at 29.4 ±0.1V
Return the Voltage Control Mode to CC.
Note: on newer models there is one extra Peak
position to STOP at the peak voltage.
Set the Voltage Control Mode Switch to Peak Stop
Verify that the Superseder will stop at the peak
voltage (as opposed to transfer from Main to
Topping).