Precision Trading 60 R3.0 Battery Charger User Manual


 
Operator Manual, Supercharger 60 R3.0
Page 29 of 62
6.3.4. RUN
6.3.4.1. Start the Charger-Analyzer in the Single Rate mode. The charger will
start to reduce the charging current when the battery voltage is within
0.5V of the float level.
6.3.4.2. The charge will terminate automatically (CYCLE END) when the
TOTAL TIME selected is reached.
6.3.4.3. The charge will terminate as a FAULT if the MONITOR CIRCUIT
detects that:
Battery temperature exceeds 45
o
C/113
o
F (BATTERY
OVERTEMP FAULT).
The actual charge current deviates from the programmed value by
more than 1A (CURRENT FAULT).
6.4 PEAK VOLTAGE CHARGE:
6.4.1. Nominal Battery Voltage
6.4.1.1. Enter the nominal battery voltage using the Cell selector (see chart on
page 19).
6.4.1.2. Select transfer from Main to Topping on Peak Voltage or stop on Peak
Voltage.
6.4.2. Charge Currents
6.4.2.1. Program the Main and Topping Charge currents as required.
6.4.3. Time
6.4.3.1. Program the Main and Total Time selectors to allow the battery to
reach the required charge level (consult battery manufacturers
specifications).
6.4.3.2. Verify that the Timer Speed is consistent with the required elapsed
time.
6.4.4. RUN
6.4.4.1. Start the Charger-Analyzer in the Dual Rate mode. If transfer on peak
is selected, the charger will transfer from Main to Topping charge
when the battery reaches the peak voltage. If stop on peak is selected,
the Charger stop upon reaching the peak voltage.
6.4.4.2. The charge will terminate automatically (CYCLE END) when the
TOTAL TIME selected is reached.
6.4.4.3. The charge will terminate as a FAULT if the MONITOR CIRCUIT
detects that:
Battery temperature exceeds 45
o
C/113
o
F (BATTERY
OVERTEMP FAULT).
The actual charge current deviates from the programmed value by
more than 1A (CURRENT FAULT).