Conair CTS 7 Saw User Manual


 
Appendix B-1 (15)
Advance Softkey
Pressing the soft key located under the word Advance on
the Table area screen. Selects the Table Advance Speed
screen.
The number shown is the current table advance speed to
encoder speed ratio. A cursor will appear in the least
significant digit. The user has a choice of ways to adjust
this number. The acceptable range is 1.20-0.80 to 1 (+/-
20%)
Exit or Prev-if no change is required press Exit or Prev to
return to the Table area screen.
Raise will increase the preset by 0.01. The key can be
pressed once for each 0.01 increment required or held down
to scroll up. Releasing the key will freeze the preset at the
last value.
Lower will decrease the preset by 0.01. The key can be
pressed once for each 0.01decrement required or held down
to scroll down. Releasing the key will freeze the preset at
the last value.
Numeric keys
Key in the speed required and press enter. The decimal
place is fixed so remember this when entering the ratio. If
you require a 1.10:1 ratio you must key in 110 and then
press enter. Keying only 11 will set the ratio to 0.11and the
out of range warning will appear on the screen for 5
seconds.
Enter or Delete?
If the keyed in number is correct press the enter key for it
to be accepted and return to the Main screen. If it is wrong
press the delete key and the previous preset will reappear.
Conair Servo
Traveling Saw
Operator Control
Instructions
TABLE SYNC. RATIO
1.00:1