CHANGING VOLTAGE
See Figures 2-4.
Your radial saw has been set up at the factory to
operate efficiently on a 120V AC single voltage circuit.
However, if heavy duty operation is required, the
circuits are overloaded, or the circuit is low voltage,
have a qualified electrician change the voltage on the
main power system to a 240V AC voltage circuit.
A WARNING: The controlcut device is set up for
a 120V AC single voltage circuit, Do not modify
the control cut cord. identify the control cut
cord and tie it back out of the way.
• Correctly identify the control cut cord, unplug it,
and set it aside.
• Unplug the main power cord.
• Remove the blade following the procedure in the
Assembly section.
• Remove the pan head screw above the blade
arbor on the motor cover. Lift motor cover to
expose switch. See Figure 2.
• Use a small screwdriver to slide the dual voltage
switch to the 240V position. See Figures 3 and 4.
• Reinstall motor cover.
• Replace the 120V plug on the main cord with a UL
listed 240V, 15 amp, 3-prong plug.
• Follow the instructions provided with the UL listed
plug.
• Plug the cord into a 240V, 15 amp, 3-blade recep-
tacle. Make sure the receptacle isconnected to a
240V AC power supply through a 240V branch
circuit that has a 15 amp fuse or circuit breaker.
Note: No adapter is available for this type of plug or
receptacle.
PANHEADSCREW
MOTORCOVER
UFT MOTORCOVERTO EXPOSESWITCH
SLIDEAS SHOWNFORSINGLEVOLTAGECIRCUITS
SWITCHSHOWNIN 110-120VOLTPOSITION
Fig. 3
LIFTMOTORCOVERTO EXPOSESWITCH
SLIDEASSHOWNFORDUALVOLTAGECIRCUITS
SWITCHSHOWNIN 220-240VOLTPOSITION
Fig. 4
BLADEARBOR Fig. 2
9 [RRFTSMRN"RADIALSAW315.220380