D-Link DSN-6410 Tool Storage User Manual


 
125
Chapter 6 Troubleshooting
6.1 System buzzer
The system buzzer features are listed below:
1. The system buzzer alarms 1 second when system boots up successfully.
2. The system buzzer alarms continuously when there is error occurred. The alarm will
be stopped after error resolved or be muted.
3. The alarm will be muted automatically when the error is resolved. E.g., when RAID 5
is degraded and alarm rings immediately, user changes / adds one physical disk for
rebuilding. When the rebuilding is done, the alarm will be muted automatically.
6.2 Event notifications
PD events
Level Type Description
INFO PD inserted Disk <slot> is inserted into system
WARNING PD removed Disk <slot> is removed from system
ERROR HDD read error Disk <slot> read block error
ERROR HDD write error Disk <slot> write block error
ERROR HDD error Disk <slot> is disabled
ERROR HDD IO timeout Disk <slot> gets no response
INFO PD upgrade started PD [<string>] starts upgrading firmware process.
INFO PD upgrade
finished
PD [<string>] finished upgrading firmware process.
WARNING PD upgrade failed PD [<string>] upgrade firmware failed.
HW events
Level Type Description
WARNING ECC single Single-bit ECC error is detected at <address>
ERROR ECC multiple Multi-bit ECC error is detected at <address>
INFO ECC dimm ECC memory is installed
INFO ECC none Non-ECC memory is installed
INFO SCSI bus reset Received SCSI Bus Reset event at the SCSI Bus <number>
ERROR SCSI host error SCSI Host allocation failed
ERROR SATA enable device
fail
Failed to enable the SATA pci device
ERROR SATA EDMA mem
fail
Failed to allocate memory for SATA EDMA
ERROR SATA remap mem
fail
Failed to remap SATA memory io space