Shutdown & Cleaning - After Hopper Method Applications
20 312079A
Shutdown & Cleaning - After Hopper Method
Applications
For short term shutdown periods (overnight to
one week) refer to Short Term Storage, page
29.
For flushing after spraying oil-based coatings,
use compatible oil-based flushing fluid or min-
eral spirits.
For flushing after spraying water-based coat-
ings, use water.
If you are using water-based materials, you
have the option of following the cleanup proce-
dure described below, or for faster cleanup,
Power Flush, starting on page 22.
1. Relieve pressure, page 7.
2. If you used a spray gun, remove tip and guard
assembly from gun and place in flushing fluid.
If you used a roller, leave roller assembly
attached to gun.
3. Pour unused paint out of
hopper and back into original
container.
4. Place drain tube in waste
pail.
5. Use inlet screen handle
to remove inlet screen
from hopper. Place it in a
bucket of clean water or
cleaning solvent.
6. Turn AllControl to
PRIME/CLEAN PUMP to
remove excess paint in
hopper.
7. If you used a liner, carefully remove liner from
hopper and dispose of it in a proper trash
container.
8. Fill a bucket with water or
cleaning solvent and pour it
into hopper.
9. Plug sprayer in grounded outlet.
10. Set AllControl to
PRIME/CLEAN PUMP.
Circulate fluid for at least a
minute.
11. Turn AllControl to OFF.
12.
a. If you used a spray gun
only, continue with Step
11.
b. If you used a roller follow Cleaning Roller
instructions beginning on page 28.
ti9292a
ti9376a
ti9378a
Step 13 is for returning paint in hose back to
paint pail. One 25-ft (7.5 m) hose holds
approximately 1-pint (1.5-liter) of paint.
ti9168a
ti9377a
ti9169a
ti9168a