Shutdown & Cleaning - After Direct Immersion Method Applications
26 312079A
Power Flush
Power flushing is a faster method of flushing. It can
only be used after spraying water-based coatings.
1. Relieve pressure, page 7.
2. If you used a spray gun, remove tip and guard
assembly from gun and place in flushing fluid.
If you used a roller, leave roller assembly
attached to gun.
3. Place waste and paint
pails side by side.
4. Lift suction tube and prime tube from paint pail.
Let them drain into paint for a while.
5. Place suction and prime tubes in waste pail.
6. Screw power flush
attachment to garden hose.
Close valve.
7. Turn on water. Open valve.
Rinse paint off suction tube,
prime tube and inlet screen.
8. Turn lever to close power
flush attachment.
9. Unscrew inlet screen from
suction tube. Place inlet screen
in waste pail.
10. Connect suction tube to Power
Flush attachment. Leave prime
tube in waste pail.
11. Open lever on Power Flush
attachment.
12. Turn AllControl to
PRIME/CLEAN PUMP.
13. Circulate water through sprayer, into waste pail
for 20 seconds.
14. Turn AllControl to OFF.
ti9726
a
ti9413a
ti9727a
TIA
TIA
TIA
OPEN
ti9169a
ti9168a