G0504 16" Horizontal Resaw Bandsaw -9-
A fire may occur if your particular electrical
configuration does not comply with local and
state codes. The best way to ensure compli
-
ance is to check with your local municipality
or a qualified electrician.
Figure 1. A power disconnect is preferable to
high current plugs and receptacles.
Serious personal injury could occur if you
allow power to the machine before complet
-
ing the setup process. DO NOT allow power
to the machine until instructed to do so.
Amperage Draw
The Model G0504 features a 220/440V motor
that is prewired for 220V and draws the following
amps under maximum load:
Motor Draw at 220V .......................... 62.2 Amps
Motor Draw at 440V ...........................31.1 Amps
Circuit Requirements
We recommend connecting your machine to
a dedicated and grounded circuit that is rated
for the amperage given below. Never replace
a circuit breaker on an existing circuit with one
of higher amperage without consulting a quali
-
fied electrician to ensure compliance with wir
-
ing codes
. If you are unsure about the wiring
codes in your area or you plan to connect
your machine to a shared circuit, consult a
qualified electrician.
220V Circuit ...........................................
80 Amps
440V Circuit ...........................................
40 Amps
3-Phase Power
SECTION 3: CIRCUIT REQUIREMENTS
Connection Type
This machine is intended to be installed in a
semi-permanent location and hardwired to the
power source by a qualified electrician, using a
supply circuit disconnect device with the capa
-
bility of being locked in the OFF (open) position
(see Figure 1).
Figure 2. Power connection points inside the
electrical box.