Grizzly G0504 Saw User Manual


 
-10- G0504 16" Horizontal Resaw Bandsaw
Converting the Model G0504 to 440V operation
consists of 1) wiring the voltage transformer, 2)
replacing the overload relays with those provided
in the G0504 440V conversion kit, and 3) rewiring
the main motor and the elevation motor. A quali
-
fied electrician must inspect all electrical modifi
-
cations before connecting to power.
Figure 3. Inside of electrical box.
In the event of an electrical malfunction or break-
down, grounding provides a path of least resis
-
tance for electric current to reduce the risk of
electric shock. This machine must be equipped
with an electric cord that has an equipment
grounding conductor. This conductor must be
grounded in accordance with all local codes and
ordinances.
Improper connections of the electrical-grounding
conductor can result in the risk of electric shock.
Check with a qualified electrician or one of our
service personnel if the grounding instructions
are not completely understood, or if you are in
doubt as to whether the machine is properly
grounded.
Electrocution or fire could
result if this machine is
not grounded correctly.
Make sure all electrical cir
-
cuits are grounded before
you connect them to the
machine. DO NOT use the
Model G0504 if it is not
grounded.
Converting to 440VGrounding
To convert the Model G0504 to 440V:
1. Disconnect the resaw from the power
source!
2. At the voltage transformer, move the T1 wire
from the 220V terminal to the 440V terminal.
Voltage Transformer
Main Motor Relay
Figure 4. Location on voltage transformer to
move the T1 wire for 440V operation.