Model G0690/G0691 (Mfg. 11/10+)
-75-
READ ELECTRICAL SAFETY
ON PAGE 74!
Model G0690 /G0691 Wiring Diagram
Ground
220V
MOTOR
Start
Capacitor
200MFD
250VAC
Run
Capacitor
25MFD
370VAC
3L2 5L3
13
NO
2T1
4T2
6T3
A1 A2
14
NO
TEST
H
97 NO
98 NO
14
12
18
16
95 NC
96 NC
2T1
4T2
6T3
OFF
CHINT
NR2-25
1L1
CHINT
NCI-18
220V
60HZ
M5
A2
ON
CHINT
NP2
Hot
Hot
Ground
220
VAC
Ground
6-20 Plug
(As Recommended)
G
Figure 131. Start
capacitor.
Figure 130.
Run capacitor.
Figure 128. Magnetic switch.
Figure 129. Motor wiring.