MAINTENANCE
36 - HUSQVARNA
8011-031
Remove the wing nut in the air lter and remove 3.
the paper lter.
IMPORTANT INFORMATION
DO NOT use compressed air over 2 bar/30 PSI
to clean the paper lter.
DO NOT wash the paper lter.
DO NOT oil the paper lter.
8011-032
Tap the paper lter against a xed surface to 4.
remove dust. If the paper lter is still dirty or
damaged, it must be replaced.
Mount the paper lter in the air lter housing and 5.
tighten the wing nut.
Ret the pre-lter on the paper lter.6.
Ret the cyclone lter with the air lter cowling.7.
Sludge Reservoir
Close the fuel valve.1.
8060-024