Table 2. Troubleshooting charts (continued)
Device Suggested action
Updating the I/O-module
configuration through the
I/O-module does not save the
management-module
NVRAM.
If you log in to the Ethernet switch module directly (through the Ethernet
switch-module Web interface or Telnet interface instead of through the management
module Web interface) and update the I/O module configuration, saving the new
configuration saves only to the I/O-module NVRAM, not to the management-module
NVRAM. The management module will not be able to communicate with the I/O
module.
See the User's Guide or Command-Line Interface Reference Guide for your
management module type for information about how to change the New Static IP
Configuration values to match the ones in Current IP Configuration, and apply the
configuration.