IBM Type 8677 Saw User Manual


 
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components
should be replaced by a field service technician.
Message Action
Remote access attempt failed. Invalid
userid or password received. User is
XXX from WEB browser
IP@=XXX.XXX.XXX.XXX
Failed attempt to log into the management module.
DHCP [X] failure, no IP @ assigned (retry
X), rc=X
Failed to get IP address by DHCP server. Check the DHCP server
connection and settings.
LAN: Command mode tamper triggered.
Possible break in attempt.
Unsuccessful attempt to access the management module in
command mode. Information only. Take action as required.
LAN: WEB server tamper delay
triggered. Possible break in attempt.
Unsuccessful attempt to access the management module in
command mode. Information only. Take action as required.
System log cleared. Information only. Take action as required.
Bus error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components
should be replaced by a field service technician.
Message Action
Failure reading I2C device. Check
devices on bus 1.
1. Reset the management module.
2. Reseat the management module.
3. Reflash the management module.
4. Replace the management module.
Failure reading I2C device. Check
devices on bus 2.
1. Reset the management module.
2. Reseat the management module.
3. Replace the management module.
4. Replace the midplane.
Failure reading I2C device. Check
devices on bus 3.
1. Reseat the power modules.
2. Reseat the management module.
3. Replace the power modules.
4. Replace the management module.
5. Replace the midplane.
Failure reading I2C device. Check
devices on bus 4.
1. Reseat the management module.
2. Reseat the cables connected to the front panel customer interface
card.
3. Reseat the cables connected to the rear panel customer interface
card.
4. Replace the front panel customer interface card.
5. Replace the rear panel customer interface card.
6. Replace the management module.
7. Replace the midplane.
76 BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide