Ingersoll-Rand 80445364 Air Compressor User Manual


 
INSTALLATION / HANDLING
23
enhttp://air.ingersollrand.com
60/50Hz IRN 20HP/ 15 kW IRN 25HP / 18.5 kW
TAS
nonTA S
TAS
nonTA S
COMPRESSOR
Nominal pressure
PSIG (bar)
150
(10.34)
150
(10.34)
Flow rate @ 150 PSIG (10.3 bar)
ACFM (m
3
/MIN)
1,
4
75
(2.12)
77
(2.18)
92
(2.61)
94
(2.66)
Flow rate @ 125 PSIG (8.6 bar)
ACFM (m
3
/MIN)
2,
4
80
(2.27)
83
(2.35)
99
(2.80)
102
(2.89)
Flow rate
@ 115 PSIG (8 bar) ACFM (m
3
/MIN)
3,
4
84
(2.38)
87
(2.46)
105
(2.97)
108
(3.06)
Airend discharge temperature. 228_F (109_C) Trip point
Ambient operating temperature
(min.) (max.)
35_F (+2_C) 104_F (+40_C)
MOTOR
Nominal power 20HP / 15kW 25HP / 18.5kW
Insulation class F
COOLING SYSTEM Air cooled
Cooling air flow 1900ft
3
/min (53.8m
3
/min)
Maximum P in air ducts 0.25 inWg (6.4mmH
2
O)
Compressed air outlet T N/A 15_F (8.3_C) N/A 20_F (11_C)
GENERAL DATA
Separation volume 1.8 gallons (7 Litres )
Coolant capacity 3.4 gallons (13 Litres )
Weight base mount unit 1350 lbs (612 kg)
Weight 120 gallon Receiver mounted 1720 lbs (780 kg)
Weight 240 gallon Receiver mounted 1891 lbs (858 kg)
Weight 500 Litre Receiver mounted 1772 lbs (804 kg)
Weight 750 Litre Receiver mounted 1891 lbs (858 kg)
DRYER ENGINEERING DATA 50 / 60Hz
Electrical protection class (std) NEMA 1
(IP 20)
Factory refrigerant charge (oz/g) 23.5 oz
667 g
Refigeration type 134 A
1 Assuming a 5 psi (0.34 bar) pressure drop through the TAS module.
2 Assuming a 8 psi (0.55 bar) pressure drop through the TAS module.
3 Assuming a 9 psi (0.62 bar) pressure drop through the TAS module.
4 Flow rate will decrease as DP through the TAS module increases.