This option can be used to optionally shut off output if an arc is not established, or is lost for a
specified amount of time. Error 269 will be displayed if the machine times out. If the value is set
to OFF, machine output will not be turned off if an arc is not established nor will output be
turned off if an arc is lost. The trigger can be used to hot feed the wire (default). If a value is set,
the machine output will shut off if an arc is not established within the specified amount of time
after the trigger is pulled or if the trigger remains pulled after an arc is lost. This is disabled
while welding in Stick, TIG or Gouge. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding parameters (run-in wire feed speed, weld
wire feed speed, electrical stick out, etc). To prevent subsequent changes to Arc Start/Loss
Error Time, the setup menu should be locked out by setting Preference Lock = Yes using the
Power Wave Manager software.
+ .;DI;!HEC.JK:I
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other
machine settings (default).
True = Voltage sensing is forced to "studs".
+ .;DI;';7:I.;B;9J?ED
Used in place of DIP switches for configuration of the work and electrode sense leads. This
option will only appear in the list if the power source has a hardware selection option. 67 pos
polarity = An electrode sense lead is connected using positive polarity. This is used by most
GMAW welding procedures.
67 neg polarity = An electrode sense lead is connected using negative polarity. This is used by
most GTAW welding procedures and some Innershield procedures.
67 & 21 = An electrode sense lead and work sense lead are connected.
Hardware Config = The hardware determines the best remote sensing configuration. This is
applicable to MIG welding procedures only.
+ 1EBJ7=;.;DI;?IFB7O
Allows viewing of Voltage Sense Lead Selection to aid in troubleshooting. The configuration is
displayed as a text string on the lower display whenever the output is enabled. This parameter
is not saved on a power cycle, but will be reset to False.
+ .>EM/;IJ(E:;I
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the
operator. To manually select a test weld mode, set this option to "Yes". When the power source
is turned off and back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and cannot be used
for welding.
+ 1?;M?7=DEIJ?9
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select
"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in
the setup menu (P.101, P.102, etc).