Lincoln Electric SVM103-C Welder User Manual


 
POWER-ARC 4000
F-5
TROUBLESHOOTING
F-5
TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the
Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-800-833-9353
OUTPUT PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
No weld output - auxiliary power
(230 - 115 VAC) operates normally -
engine runs normally.
1. Check continuity (zero ohms) of
lead W1A (black) from output
terminal to reactor (L1). See the
Wiring Diagram.
2. Check continuity (zero ohms) of
lead W2 (black) from output
terminal to stator winding. See
the Wiring Diagram.
3. Check continuity (zero ohms) of
lead W1 (black) from reactor (L1)
to stator winding. See the
Wiring Diagram.
4. Check reactor (L1) for continuity
of winding. See the Wiring Dia-
gram.
5. Check the stator for continuity of
winding. See the Wiring Dia-
gram.
6. Make certain the reactor and/or
stator are NOT grounded. Mini-
mum acceptable resistance to
ground is 500 K-ohms.
1. Check the open circuit voltage
(OCV) at the welder output termi-
nals. If OCV is okay, go to Step
2, below.
If OCV is not present at the welder
output terminals, contact your
local Lincoln Electric Authorized
Field Service Facility.
2. Check the welding cables,
clamps and electrode holder for
loose or broken connections.
CAUTION