POWER MIG 300 SCROLLING DASHES TEST (continued)
TEST PROCEDURES:
For Machines with code 10952, 10958
and 11000.
1. Hold “select” switch up while powering up
machine.
2. Release “select” switch when displays show
“PrESSPin”.
3. Turn the right “encoder knob” until displays
show “CLrAll”.
4. Toggle the “select” switch up and release.
5. Machine will reset itself.
For Machines with code 10562.
1. Hold “select” switch up while powering up
machine.
2. Continue to hold “select” switch up and turn
right “encoder” until display reads “CLrAll”.
3. Release the “select” switch.