RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
No Load RPM Load RPM
Maximum Speed 3725 3650
Minimum Speed 3675 3400
WELDER/GENERATOR OUTPUT
1
Output Control Field Volts Field Amps Open Circuit Load Volts Load Amps
Volts
Maximum 43 - 49 4.8 - 5.8 60 - 63 12 - 25 120 - 125
Minimum ––55 - 60 14 - 27 75 - 85
AUXILIARY POWER RECEPTACLE OUTPUT
1
230 Volt Receptacle 115 Volt Receptacle
22
Output Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Control Volts Volts
Maximum 236 - 248 215 - 230 18 - 20 123 - 129 112 - 120 18 - 20
1
Current Control Dial set at MAXIMUM or GENERATOR.
2
Output values of each receptacle can vary within the range shown