TROUBLESHOOTING & REPAIR
F-44 F-44
Classic III and IIID
FIGURE F.18 - LEAD DISCONNECTION POINTS
YELLOW AND WHITE WIRE
IN-LINE CONNECTORS;
YELLOW LEADS; BLACK
CURRENT TRANSFORMER
LEAD
ALL LOCATED BEHIND
CASE FRONT
ALTERNATOR STATOR REMOVAL
AND REPLACEMENT (continued)
FIGURE F.19- LEAD DISCONNECTION – CIRCUIT BREAKER, RECEPTACLES, FIELD BRIDGE RECTIFIER
230 VAC RECEPTACLE
CB1 CIRCUIT BREAKER
115 VAC RECEPTACLE
CB4 CIRCUIT BREAKER
FIELD FUSE HOLDER
FIELD RECTIFIER BRIDGE