Miller Electric IH Welder User Manual


 
OM-203 185 Page 54
Trouble Remedy
2408 Temperature Controller reads
greater than 5° F different than
Channel 1 on 5100V Recorder.
See Section 8-3I.
2408 Temperature Controller
readings fluctuate rather than
remain stable.
Check and secure connections to the workpiece.
5100V Recorder screen blinks
when touched, but does not
advance to next screen.
Screen calibration needs adjusting. Turn off IHTS power switch. Turn on IHTS power switch while touching
screen, and continue to touch screen (about 45 seconds) until configuration display appears on the screen.
Press “Touch Cal” or wait a few minutes for the Touch Cal display to appear on the screen. Use a pointed object
(be careful not to damage screen), and touch each set of cross hairs to calibrate screen. When calibration
is complete, turn IHTS power off and back on again.
5100V Recorder does not recognize
floppy disk
Floppy disks do not work well in ambient temperatures greater than 104° F (40° C).
floppy disk.
Clean floppy drive with a disk drive cleaner (available from a local computer reseller).