4 Installation
Install and set up the product according to the following conditions.
4.1
Installation conditions
1) Ambient temp.: Controller: 0 to +35°C
Head: +5° to +35°C
2) Relative humidity: 30 to 85% (at 25°C, no condensation)
3) When setting up the controller, make sure that its rubber feet are
horizontally level.
4) To prevent damage due to overheating, make sure that the area around the
controller is free of any obstructions.
5) The dimensions of the controller are 80 mm (L) × 130 mm (H) × 145 mm
(D), but remember that the controller will have one or more LED heads
attached during use. The radius of the LED head connector cable should
be no less than 33 mm, otherwise the cable may become damaged.
Never place anything on top or below the controller, or obstruct the
ventilation openings in any way. Otherwise, overheating and burning may
occur.
If using more than one controller, do not bundle
the supplied AC adapters together. Otherwise, the
AC adapters may overheat and fail.
Ensure that there is enough space
above and on the sides of the
controller.
Warning
WarningWarning
Warning
Warning
WarningWarning
Warning
Wall
Wall
Approx. 50 mm
Approx. 20 mm