External control
43
2) “Replacement time (×100hrs)”… To set the LED replacement time
(* While changing replacement time settings, “Replacement time (×100hrs)” is highlighted.
・Read Reads the current replacement time setting from the UJ35 controller into the PC.
・Write Uploads the current replacement setting from the PC to the UJ35 controller.
・Cancel Cancels the current replacement time setting operation and reverts to the original settings.
5. Using the Type Set screen
… For particular Type 0-7), select the CH.
… For particular Type (0-7), enter the program settings (STEP (%, s) for particular CH (1-4).
*When new CH settings are being entered, Type Change is highlighted.
Lower graph: orange bar, irradiation enabled timing; gray bar, irradiation disabled timing
・[TYPE(0-7)] Selects particular TYPE (0–7) for setting and read out.
・[CH(1-4)] Selects particular TYPE CH (1–4) for setting and read out.
・[UV.PWR(0-100)]
For each STEP (1–10) enter UV strength (0%–100%) or display values read from UJ35 controller.
・[TIME(0.0-999, CON)]
For each STEP (1–10) enter irradiation time (0–999 s, CON) or display values read from UJ35 controller.
・Copy Copies settings for STEP 1–10.
・Paste Pastes copied settings for STEP 1–10.
・Read Reads the current TYPE CH (CH1 only) settings from the UJ35 controller.
・Write
Uploads current TYPE CH (CH1 only) settings and CH selection from computer to UJ35 controller.
・Cancel Cancels current setting entry operation and return to start.