Panasonic 35 Work Light User Manual


 
Operation modes
17
6.2 UV measurement and Auto tuning mode
It is possible to make UV measurements and Auto tunings.
* To use this mode it is necessary to have a compatible UV sensor (option).
Operation
1) Measuring UV intensity
(1) Connecting a UV sensor
1. While in operation mode, press the UV CHK switch.
2. The intensity setting value (green) and intensity measurement
value (red) will be displayed.
3. Select the CH for UV intensity measurement.
4. While the intensity setting value (green) and intensity measurement
value (red) are displayed, hold down the SET switch.
5. The intensity setting value (green) is displayed.
6. Use / to change the intensity setting value to “---.”
7. Press the SET switch.
8. The intensity setting value (green) and intensity measurement
value (red) are displayed.
9. Press the EMISSION switch to start irradiation and begin the UV
intensity measurement. The irradiation modulation (%) and measured
intensity value (W/cm2) are displayed.
10. Press EMISSION again to stop irradiation.
* Press the MODE switch to switch the measurement range.
(0.00 range/00.0 range)
* If a measured value exceeds the measurement range the display value
will start flashing.
(2) Making a UV measurement
* It is possible to change the irradiation modulation (%) during a UV
intensity measurement, using /.