2.2 DC bus data
Single-phase drives
LXM32∙... U45M2 U90M2 D18M2 D30M2
Nominal voltage (1 ∼) V 115 230 115 230 115 230 115 230
Nominal voltage DC bus V 163 325 163 325 163 325 163 325
Undervoltage limit V 55 130 55 130 55 130 55 130
Voltage limit: activation of Quick Stop V 60 140 60 140 60 140 60 140
Overvoltage limit V 450 450 450 450 450 450 450 450
Maximum continuous power via DC bus kW 0.2 0.5 0.4 0.9 0.8 1.6 0.8 2.2
Maximum continuous current via DC bus A 1.5 1.5 3.2 3.2 6.0 6.0 10.0 10.0
Three-phase drives
LXM32∙... U60N4 D12N4 D18N4 D30N4 D72N4 D85N4 C10N4
Nominal voltage (3 ∼) V 208 208 208 208 208 208 208
Nominal voltage DC bus V 294 294 294 294 294 294 294
Undervoltage limit V 150 150 150 150 150 150 150
Voltage limit: activation of Quick Stop V 160 160 160 160 160 160 160
Overvoltage limit V 820 820 820 820 820 820 820
Maximum continuous power via DC bus kW 0.4 0.8 1.7 2.8 6.5 7.0 11.0
Maximum continuous current via DC bus A 1.5 3.2 6.0 10.0 22.0 28.0 40.0
LXM32∙... U60N4 D12N4 D18N4 D30N4 D72N4 D85N4 C10N4
Nominal voltage (3 ∼) V 400 400 400 400 400 400 400
Nominal voltage DC bus V 566 566 566 566 566 566 566
Undervoltage limit V 350 350 350 350 350 350 350
Voltage limit: activation of Quick Stop V 360 360 360 360 360 360 360
Overvoltage limit V 820 820 820 820 820 820 820
Maximum continuous power via DC bus kW 0.8 1.6 3.3 5.6 13.0 15.0 22.0
Maximum continuous current via DC bus A 1.5 3.2 6.0 10.0 22.0 28.0 40.0
LXM32∙... U60N4 D12N4 D18N4 D30N4 D72N4 D85N4 C10N4
Nominal voltage (3 ∼) V 480 480 480 480 480 480 480
Nominal voltage DC bus V 679 679 679 679 679 679 679
Undervoltage limit V 350 350 350 350 350 350 350
Voltage limit: activation of Quick Stop V 360 360 360 360 360 360 360
Overvoltage limit V 820 820 820 820 820 820 820
Maximum continuous power via DC bus kW 0.8 1.6 3.3 5.6 13.0 15.0 22.0
Maximum continuous current via DC bus A 1.5 3.2 6.0 10.0 22.0 28.0 40.0
2 Technical Data
LXM32
16
Common DC bus
MNA01M001EN, V1.01, 08.2014