Schneider Electric MNA01M001EN Welding System User Manual


 
5.1.2 Supply via the DC bus
Commissioning steps:
Verify proper installation of the drives and the connections for the
common DC bus, see chapter "4.3 Verifying installation", page 49.
Switch on the controller supply for all devices.
LXM32: Set the parameter MON_MainsVolt to "DC-Bus Only" for
LXM32.
Parameters Value
MON_MainsVolt
DC-Bus Only
LXM32: Set the parameters for the braking resistors of LXM32
drives, see chapter
"5.2 LXM32: Setting the braking resistor parameters".
Commission the drives, see the descriptions in the manuals for the
individual products.
LXM32
5 Commissioning
Common DC bus
53
MNA01M001EN, V1.01, 08.2014