<Caution>
z The battery charge monitor cannot detect the degradation of the battery nor the
battery fluid level. Check the battery fluid level periodically. (Refer to No. 6-5
Checking Battery)
(3) Oil Pressure Monitor Lamp
Danger : Injuries
z Close all doors and place locks during operating this equipment, to avoid
injuries by unintentionally touching cooling fan and fan belt.
Caution : Burns
z Do not touch the engine and muffler during operation and immediately after
stopping the equipment, for the temperature can reach extremely high.
z When checking engine oil, always stop the engine, and wait until the engine
cools down. If you open either the oil gauge or the oil filter cap during operation,
hot oil may cause some injury.
When the engine oil pressure drops during operation, the oil pressure monitor lamp will
flash, and the automatic shutoff will be engaged.
When this occurs, check the engine oil level, and replenish to the maximum level if
needed.
<Caution>
z The engine oil pressure monitor cannot detect the degradation of engine
oil itself. Please check the engine oil periodically, and change if needed.
(Refer to No. 11. Maintenance.)
z Check the fuse next, when the abnormality, other than WATER TEMP,
BATTERY CHARGED OR OIL PRESSURE is detected. If the fuse is burned
out, consult with our authorized distributor or our engineering section, because
there may be an abnormality of electric/electronic parts or wiring and repairing
may be required.
(4) Hz/Overheat Monitor Lamp
z Unless the frequency selector lever position
and the bus bars in the equipment are
correspondent to each other, Hz/OVERHEAT
monitor lamp will turn ON.
z Hz/OVERHEAT monitor lamp may flash
in the case the machine is used excessively
over the duty cycle.
<Caution>
z When Hz/OVERHEAT monitor turns ON, as the output power reduces
remarkably, the AC output power can hardly be used.
z There may be a case that the lamp will not flash, depending on the welding
type or the weather condition.